United States · Licensing exam

Plumbing exam

There’s no national plumbing exam. Each state sets its own license rules, and some cities do too. Exams are based on the plumbing code your state adopts, usually the International Plumbing Code (IPC) or the Uniform Plumbing Code (UPC), and companies like PSI and Pearson VUE run them. This guide explains how it usually works and gives the official facts for Texas, Washington and North Carolina. There’s a free practice test further down, on drainage, venting, traps, water supply and backflow.

  • 70%Pass mark in Texas and Washington
  • 100Written questions on the Texas journeyman exam, in 2 hours
  • 100 + 25 + 25Washington journey level: code questions, plus two sizing drawings
  • 4 hoursNorth Carolina plumbing contractor technical exam, plus 1.5 hours of business and law

Key facts

At a glance

Who sets it
Your state, and in some places your city. Rules differ a lot
Based on
The IPC or the UPC, whichever your state adopts, often with state changes
North Carolina
Contractor license, open book exam, $150 per exam

How it works

A computer-based code exam set by your state, sometimes with a hands-on part

  1. There’s no national plumbing license. Each state sets its own rules, and some cities license plumbers too.
  2. You usually prove your hours and get approved by the state first. Only then can you book the exam.
  3. Most exams are multiple choice, on a computer, at a test center run by a company like PSI or Pearson VUE.
  4. Exams are based on the plumbing code your state uses, usually the International Plumbing Code (IPC) or the Uniform Plumbing Code (UPC), often with state changes.
  5. Texas: the journeyman exam has a 100-question written part in 120 minutes at Pearson VUE, then a hands-on practical in Austin or Waco. You need 70%.
  6. Washington: the journey level exam is closed book, with 100 code questions plus a waste-and-vent sizing drawing and a water-sizing drawing. Each part is 90 minutes, and you need 70% on all three.
  7. North Carolina licenses plumbing contractors rather than journeymen. The exam is open book, with your own approved code books, and PSI runs it.

Topics

What’s on the test

01

Sanitary drainage

How waste water leaves a building by gravity: the parts of the system, slope, fittings and cleanouts.

Key points (4)
  • A soil pipe carries discharge from water closets and urinals. A waste pipe carries liquid waste without fecal matter.
  • The building drain runs inside the building. The building sewer starts just outside and carries waste to the public sewer or a private system.
  • Small horizontal drains generally need at least 1/4 inch of fall per foot.
  • Sanitary tees are for horizontal-to-vertical joins. Horizontal-to-horizontal joins use wyes or combination wye and eighth bends.
02

Vents and venting

Why drains need air, and the common ways to vent fixtures.

Key points (4)
  • Vents protect trap seals from siphonage and back pressure and carry sewer gas outdoors.
  • A wet vent also carries drainage from other fixtures. Codes limit its size and layout.
  • A dry vent connects above the centerline of a horizontal drain, so waste doesn’t run into it.
  • Horizontal dry vents generally rise above the flood-level rim of the fixtures they serve before running sideways.
03

Traps and trap seals

The water seal that keeps sewer gas out, and the traps codes allow and ban.

Key points (4)
  • A trap seal should be at least 2 inches and no more than 4 inches deep.
  • S-traps, bell traps and traps that depend on moving parts are generally prohibited.
  • A fixture must not be double trapped.
  • Seals are lost by siphonage, back pressure and evaporation. A trap primer keeps a rarely used floor drain trap full.
04

Water supply and distribution

Getting safe water to fixtures at the right pressure, with the right materials.

Key points (4)
  • Copper wall thickness, thickest to thinnest: Type K, Type L, Type M.
  • Static pressure above 80 psi generally needs a pressure-reducing valve.
  • Water hammer arresters absorb the surge from quick-closing valves.
  • Water piping must be protected from freezing and physical damage.
05

Cross-connections and backflow

How contaminated water can flow back into drinking water, and how to stop it.

Key points (4)
  • Back-siphonage is caused by low or negative pressure in the supply. Back pressure is caused by higher pressure downstream.
  • An air gap is an open vertical space between an outlet and the flood-level rim. It’s the most reliable protection.
  • Hose connections need a vacuum breaker.
  • Testable backflow assemblies are tested by certified testers. Rules differ by state and water supplier.
06

Fixture units and pipe sizing

Rating fixture loads and using the code tables to size drains, vents and water pipes.

Key points (4)
  • Drainage fixture units (DFUs) rate the load a fixture puts on the drain. Add them up and use the table for pipe size.
  • Water supply fixture units (WSFUs) rate probable water demand for sizing supply pipes.
  • Some exams, like Washington’s, include sizing exercises from a drawing.
  • Always size from the tables in the code your exam uses, because IPC and UPC tables differ.
07

Pipe materials and joints

Common pipe materials and how each is joined, following the manufacturer’s instructions.

Key points (4)
  • PVC solvent joints: clean, prime where required, cement, then push fully home and hold.
  • Different metals in contact can corrode. A dielectric fitting separates copper from steel.
  • Codes refer to manufacturer’s instructions for many joints, so read the labels on primer, cement and flux.
  • Texas’s practical exam has you join PVC, copper, threaded steel and cast iron.
08

Water heaters and job safety

Safe water heater installs and the basic jobsite safety plumbers are expected to know.

Key points (4)
  • A T&P discharge pipe is full size, drains by gravity, and has no valve or cap.
  • OSHA generally requires a protective system in trenches 5 feet deep or more.
  • Texas’s practical exam asks you to spot code violations on real water heater installs.
  • Many plumbing exams include fuel gas questions, so check your bulletin.

Free practice test

Try 20 questions on plumbing basics

These 20 questions are our own. They cover the basics every plumbing code shares: drainage and venting, traps, water supply, backflow, fixture units, pipe materials and safety. The real exam depends on your state. The Texas journeyman written exam, for example, has 100 questions. Texas and Washington both use 70% as the pass mark, so 14 right out of 20 is a pass here. After each answer you can ask the tutor to explain it another way.

Question 1 of 20

What is a pipe that carries the discharge from water closets (toilets) called?

Sample of the exam: same format, 20 questions.

Test day

What to bring on exam day

  • A valid, unexpired government-issued photo ID with your signature, in the exact name you registered under
  • Your approval or authorization notice from the state, if your bulletin asks for it. Washington does
  • A silent, non-programmable calculator with no letter keys, where allowed. Washington allows one
  • Your own tabbed code books, only if your exam is open book, as in North Carolina
  • For the Texas practical: long pants and closed-toe shoes. The board supplies the materials

Before you go

  1. Check your state’s licensing board page, and your city’s if it licenses plumbers. Hours, exams and fees differ a lot.
  2. Log your work hours from day one. Texas and Washington both want them verified by employers.
  3. Download your state’s candidate handbook or bulletin. It says which code edition is tested and what you may bring.
  4. Study the code edition your exam uses, starting with the definitions chapter.
  5. Practice sizing drains, vents and water pipes from fixture units if your exam has drawings.
  6. If your exam is open book, tab your code book before test day, within the bulletin’s rules.
  7. Arrive 30 minutes early. If you’re late you can be turned away and lose your fee.
TSBPE: Journeyman Plumber licenseIn Texas you apply to the TSBPE, then book the written exam with Pearson VUE once you get an Authorization to Test. Washington exams are booked with PSI after L&I approves you, and North Carolina’s with PSI after the board approves you.

Study options

Where to study

Start with two things: your state’s candidate handbook or bulletin, which is free and tells you what’s tested, and the edition of the plumbing code your exam uses. Most people learn the trade through an apprenticeship. We’ve compared the official guides, apps and training programs people use.

OptionPriceFree to useLinks
Official and free
Texas plumbing candidate handbook and review courses (TSBPE and Pearson VUE)Official · PDFThe handbook lists every Texas plumbing exam with its question count, time, fee and the 70% pass mark. The journeyman review course explains what the practical involves and has sample questions for each code chapter.
FreeThe full handbook and the journeyman and tradesman review courses
Washington L&I plumbing candidate bulletin (PSI)Official · PDFShows each Washington plumbing exam with its number of items, time, pass mark and whether it’s open or closed book. It also covers fees, ID rules, calculators and retakes.
FreeThe full bulletin
North Carolina exam book list and applicant informationOfficial · Web and PDFNorth Carolina’s exams are open book, so the book list matters. It names every code book you need for each license and the rules for tabbing them. The board also sells its laws and rules book and business book.
FreeThe book list, exam rules and applicant information
IAPMO: Uniform Plumbing Code onlineCode publisher · WebsiteUseful if your state uses the UPC, as Washington does. Make sure you read the same edition your exam is based on, with any state amendments.
Read online on the site. Printed copies are paidRead-online versions of the UPC from the 2012 to the 2027 edition
Apprenticeship.gov Apprenticeship FinderUS Department of Labor · WebsiteA registered apprenticeship can count toward your license in many states. In Texas it replaces the 48-hour classroom training needed for the journeyman exam.
FreeSearch for registered plumbing apprenticeships near you
Apps and websites
Journeyman Plumber Exam Prep (Nilu Rathod)App · iPhone and iPadRated 4.6 from 160 ratings on the App Store. Practice tests and a mock test for state journeyman written exams. It isn’t tied to one state’s code edition, so use it alongside your code book.
Free download. Lifetime premium $12.99The download. The listing doesn’t say how much is free before you upgrade
Journeyman Plumber Test Prep (S Mehta)App · iPhone and iPadRated 4.7 from 59 ratings on the App Store. Around 1,000 practice questions, timed tests and progress tracking.
Free with ads. Ad removal from $2.99 to $4.99The practice questions, with ads
In person
UA plumbing apprenticeship (United Association)Union apprenticeshipThe UA is the union for plumbers and pipefitters. Its apprenticeships combine paid work with classroom training and leave you with no student debt. You apply through a local union.
Paid work. Contact your local union for detailsYou earn wages and benefits from day one
TSBPE-approved training providers (Texas)Classroom trainingIf you aren’t in a registered apprenticeship, Texas requires 48 hours of approved training before the journeyman exam, including OSHA 10-Hour and code courses. Only courses from a TSBPE-approved provider count.
Set by each providerThe list of approved providers is free
Community colleges and trade schoolsCertificate and degree programsSchooling can count toward your hours in some states. North Carolina counts approved college credit for up to half the experience you need. Ask how a program’s hours count in your state before you enroll.
Tuition varies a lotAsk each school

Prices and ratings checked October 2026.

FAQ

Common questions

How many questions are on the journeyman plumbing exam?

It depends on your state. As of October 2026, the Texas journeyman exam has a written part with 100 questions in 120 minutes, plus a practical with 6 parts in 240 minutes. Washington’s journey level exam has 100 code questions and two sizing drawings with 25 items each, and each part gets 90 minutes. Check your own state’s bulletin for its numbers.

What score do I need to pass?

70% in Texas and Washington. In Texas you need to pass both the written and practical parts. In Washington you need 70% on all three parts, and if you fail one, you retake all three. North Carolina’s board doesn’t give its pass mark on the pages we read, so ask the board.

Is the plumbing exam open book?

It depends on the state. Texas and Washington journeyman exams are closed book. Washington prints a few sizing tables for you. North Carolina is open book: you bring your own approved code books, and you can tab them with permanent tabs.

How many hours do I need before I can take the exam?

In Texas you need 8,000 hours in the trade for the journeyman exam, plus 48 hours of approved classroom training unless you’re in a registered apprenticeship. Washington’s journey level certificate needs 8,000 hours, with at least 4,000 on commercial or industrial work. North Carolina’s plumbing contractor exam needs 4,000 hours, and up to half can come from approved schooling.

How much does it cost to get a plumbing license?

As of October 2026, a Texas journeyman costs $40 to apply, $68.50 for the written exam, $40 for the practical and $40 for the license, plus $39.05 for fingerprints. Washington charges $202.10 per exam application, plus $84 to PSI. North Carolina charges $150 per exam. Training is the bigger cost, though apprentices get paid while they learn.

What’s the difference between a journeyman and a master plumber?

A journeyman can do plumbing work on their own. A master can usually also run jobs, pull permits or be responsible for a plumbing business, and needs more experience. In Texas, you can take the master exam after holding a journeyman license for 4 years, or 1 year if you finished a registered apprenticeship. The Texas master exam has 308 questions in 6 hours, plus an optional 30-minute break.

All 20 practice questions with answersA printable list of the practice test above
  1. What is a pipe that carries the discharge from water closets (toilets) called?

    Soil pipe A soil pipe carries discharge that contains human waste, which means anything from water closets, urinals and similar fixtures. A waste pipe carries liquid waste without fecal matter, like water from sinks and tubs.

  2. In general, what is the minimum slope for a horizontal drainage pipe 2 inches in diameter?

    1/4 inch per foot Both the IPC and the UPC use 1/4 inch of fall per foot as the basic minimum for small horizontal drains like a 2-inch line. That slope keeps water moving fast enough to carry solids. Larger pipes can be allowed a flatter slope, so check the sanitary drainage chapter of your code.

  3. You need to join a horizontal branch drain to a horizontal building drain. Which fitting is the right choice?

    A wye, or a combination wye and eighth bend A sanitary tee is meant for a horizontal pipe flowing into a vertical one. Where one horizontal drain joins another, codes call for a fitting with a long, gentle turn, like a wye or a combination wye and eighth bend. It brings the flow in at an angle, in the same direction as the main flow.

  4. What is the main purpose of a plumbing vent system?

    To protect trap seals from siphonage and back pressure Vents let air move in and out of the drainage system. That keeps air pressure near normal in the pipes, so moving water doesn’t suck a trap dry (siphonage) or push the seal out (back pressure). Vents also carry sewer gas safely outdoors, above the roof.

  5. What is a wet vent?

    A vent pipe that also carries drainage from other fixtures A wet vent is a pipe that does two jobs: it vents one or more fixtures and also carries drainage from others. Codes allow it only in set layouts and sizes, because the pipe has to stay big enough to carry water and still move air.

  6. Where should a dry vent connect to a horizontal drain?

    Above the centerline of the drain A dry vent is taken off above the centerline of a horizontal drain, then rises before running horizontally. That keeps waste water from flowing into the vent, where it could leave deposits and block it over time.

  7. How deep should the water seal in a fixture trap be?

    Between 2 and 4 inches Both the IPC and the UPC call for a trap seal of at least 2 inches and no more than 4 inches, with only a few exceptions. Less than 2 inches is easily lost to siphonage or evaporation. More than 4 inches makes the trap hold back solids and clog.

  8. Which of these trap types is generally not allowed by plumbing codes?

    An S-trap An S-trap drops straight down after the bend, so the rushing water can siphon the seal out of the trap. Codes generally prohibit S-traps. A vented P-trap is the standard choice for most fixtures.

  9. Why shouldn’t a fixture drain through two traps, one after the other?

    Air trapped between the traps can slow or stop drainage Codes don’t allow double trapping. The air caught between two water seals has nowhere to go, so it acts like a plug. The fixture drains slowly or not at all, and the seals can be forced out.

  10. Which type of copper water tube has the thickest wall?

    Type K For the same size tube, Type K has the thickest wall, Type L is in the middle and Type M is the thinnest. That’s why Type K is often used underground and for water services, where the pipe needs to be toughest.

  11. What does a water hammer arrester do?

    Absorbs the pressure surge when a valve closes quickly When a quick-closing valve, like a washing machine or dishwasher valve, snaps shut, the moving water slams to a stop. That sends a pressure spike through the pipe, which you hear as a bang. A water hammer arrester has an air or gas cushion that absorbs the spike.

  12. The static water pressure coming into a building is above 80 psi. What do codes generally require?

    A pressure-reducing valve Both the IPC and the UPC set 80 psi as the upper limit for static pressure in a building’s water system. Above that, you install an approved pressure-reducing valve to bring it down. High pressure wears out valves and fixtures and makes water hammer worse.

  13. What is an air gap, in backflow prevention?

    An open vertical distance between a water outlet and the flood-level rim of the fixture An air gap is an unobstructed vertical space between the end of a water outlet and the flood-level rim of the fixture or tank it fills. Because there’s no physical connection, dirty water can’t be pulled back into the supply. Codes set a minimum gap based on the size of the outlet.

  14. A garden hose is left in a bucket of weed killer. A water main breaks nearby and the weed killer is sucked into the house’s water pipes. What is this called?

    Back-siphonage Back-siphonage happens when pressure in the supply drops below atmospheric pressure, creating a partial vacuum. Here the main break pulled the liquid back up the hose. A vacuum breaker on the hose connection would have stopped it.

  15. What is a drainage fixture unit (DFU)?

    A measure of a fixture’s probable discharge into the drainage system, used to size drains A drainage fixture unit is a way of rating how much load a fixture puts on the drainage system, allowing for how much it discharges, how fast and how often. You add up the DFUs on a pipe and use the code tables to find the minimum pipe size.

  16. What are water supply fixture units (WSFU) used for?

    To size water supply piping from the probable demand of the fixtures Water supply fixture units rate how much water a fixture is likely to demand. You total them for each section of pipe, then use the code’s tables or method, along with pressure and length, to find the pipe size. They’re a separate system from drainage fixture units.

  17. You’re making a solvent-cement joint in PVC pipe. What goes on first, once the pipe is cut and deburred?

    Primer, where the code or manufacturer requires it For PVC, you clean and prime the pipe and the inside of the fitting, then apply solvent cement and push the pipe fully into the fitting. Primer softens the surface so the cement can fuse the plastic. Follow the manufacturer’s instructions on the cans, which is what codes refer to.

  18. Why would you use a dielectric union between copper and galvanized steel pipe?

    To prevent galvanic corrosion between the two metals When two different metals touch in water, they act like a battery and one of them corrodes faster. A dielectric fitting separates copper from steel with an insulating gasket and sleeve, so current can’t flow between them.

  19. Which is an acceptable way to run the discharge pipe from a water heater’s temperature and pressure (T&P) relief valve?

    Full size of the valve outlet, draining by gravity to an approved place The T&P discharge pipe must not be smaller than the valve outlet, must drain by gravity, and must end where hot water won’t hurt anyone or damage the building. It can never have a valve or a cap. If it’s blocked, the relief valve can’t do its job and the tank could fail.

  20. Under federal OSHA rules, at what depth does a trench generally need a protective system, such as sloping, shoring or a trench box?

    5 feet OSHA’s excavation rule (29 CFR 1926.652) requires a protective system in trenches 5 feet deep or more, unless the trench is made entirely of stable rock. Shallower trenches still need one if a competent person sees signs of a possible cave-in.