United States · Certification test

EPA 608 certification: the refrigerant handling test

You need EPA 608 certification before you work on the refrigerant circuit of air-conditioning or refrigeration equipment in the US. The rule comes from Section 608 of the Clean Air Act. The Environmental Protection Agency (EPA) writes the test questions, and you take the test with a certifying organization EPA has approved. You pick Type I for small appliances, Type II for high-pressure systems, Type III for low-pressure systems, or all three for Universal. The certification doesn’t expire.

  • 25Questions in each section
  • 70%Passing score, closed-book test
  • 30 daysLongest wait for your results and card
  • 100Questions for Universal certification

Key facts

At a glance

Rules set by
EPA, in the Code of Federal Regulations (40 CFR Part 82)
Test given by
An EPA-approved certifying organization
Who needs it
Anyone who opens a refrigerant circuit, except vehicle air conditioning
Types
Type I, Type II, Type III or Universal
How you test
In person or online with a proctor; Type I also open-book or by mail
How long it lasts
For life, unless EPA revokes it

How it works

How the EPA 608 certification test works: 25 questions a section

Closed-book test
70%
Mail-in test
84%
To pass you need at least 70% on the closed-book test, and at least 84% on the mail-in test.
  1. You take the test with one of the certifying organizations EPA has approved. EPA writes the question bank but doesn’t give the test itself.
  2. Every test has a Core section plus one section for each type you want. Each section draws 25 questions from EPA’s bank, and programs use several versions at each sitting.
  3. Type II, Type III and Universal tests are closed-book and proctored in a secure setting. No notes or training materials are allowed.
  4. Type I can also be taken in a mail-in or open-book format, but an open-book Core or Type I score can’t be used toward Universal.
  5. The proctor checks your photo ID before the test, and collects every test form, answer sheet and piece of scratch paper afterwards.
  6. You get a handout or message after the test that names the program and the proctor and says when your score and card should arrive.

Topics

What’s on the test

01

Core: ozone depletion and refrigerant types

Why chlorine in refrigerants harms the ozone layer, and how to tell a CFC from an HCFC or an HFC.

Key points (4)
  • EPA expects you to know that R-12 is a chlorofluorocarbon (CFC), R-22 a hydrochlorofluorocarbon (HCFC) and R-134a a hydrofluorocarbon (HFC), not their chemical formulas (EPA Section 608 Test Topics, Core).
  • CFCs have a higher ozone depletion potential than HCFCs, and HCFCs higher than HFCs (EPA Section 608 Test Topics, Core).
  • HFCs contain no chlorine, so their ozone depletion potential is 0, though some have a high global warming potential (EPA Section 608 Test Topics glossary).
  • Core questions cover the environmental impact of CFCs, HCFCs and substitute refrigerants (40 CFR Part 82, Subpart F, Appendix D, section d).
02

Core: the Clean Air Act and Section 608 rules

The venting ban, the sales restriction, phaseout dates and the other Section 608 rules every technician is tested on.

Key points (4)
  • Knowingly venting ozone-depleting or substitute refrigerant while servicing or disposing of equipment is prohibited; only de minimis releases, normal operating leaks and exempt substitutes are allowed (EPA Prohibition on Venting Refrigerants).
  • Only certified technicians, or employers of one, may buy refrigerant for stationary equipment, except small cans of substitute refrigerant for car air conditioning (EPA Refrigerant Sales Restriction).
  • Recovered refrigerant that changes owner must first be reclaimed to the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 700 purity standard by an EPA-certified reclaimer (EPA Service Practice Requirements; Section 608 Test Topics).
  • The rule covers air-conditioning and refrigeration equipment except motor vehicle air conditioners (MVACs), which fall under Section 609 (EPA Section 608 Test Topics; EPA Section 608 and 609 Overlap).
03

Core: recovery, evacuation, safety and shipping

The three Rs, recovery techniques, dehydration, cylinder safety and labeling, the hands-on side of the Core section.

Key points (4)
  • Recover means removing refrigerant into an external container without necessarily testing or processing it; reclaim means reprocessing it to AHRI 700-2016 purity (EPA Section 608 definitions).
  • Core covers the risk of filling cylinders more than 80 percent full and never refilling disposable cylinders (EPA Section 608 Test Topics, Core).
  • Use nitrogen, not oxygen or compressed air, for leak testing, with a pressure regulator and relief valve (EPA Section 608 Test Topics, Core).
  • Refrigerant cylinders need a label naming the refrigerant and a Department of Transportation (DOT) classification tag (EPA Section 608 Test Topics, Core).
04

Type I: small appliances

Recovery from factory-sealed appliances with 5 pounds of refrigerant or less, such as household refrigerators and window units.

Key points (4)
  • A small appliance is fully manufactured, charged and hermetically sealed in a factory with 5 pounds or less of refrigerant (40 CFR 82.152).
  • Recover 90 percent of the charge with post-November 15, 1993 recovery equipment and a working compressor, or 80 percent with older equipment or a dead compressor; 4 inches of mercury vacuum also meets the rule (EPA Service Practice Requirements).
  • With an inoperative compressor and a passive recovery device, install both high- and low-side access valves (EPA Section 608 Test Topics, Type 1).
  • Remove solderless access fittings at the end of service (EPA Section 608 Test Topics, Type 1).
05

Type II: high-pressure appliances

Leak detection, leak repair rules and evacuation levels for high- and very high-pressure systems such as split systems and supermarket refrigeration.

Key points (4)
  • A high-pressure appliance uses a refrigerant with a saturation pressure between 170 and 355 pounds per square inch absolute (psia) at 104°F, such as R-22, R-407C or R-410A (40 CFR 82.152).
  • With post-1993 recovery equipment, high-pressure appliances under 200 pounds go to 0 inches of mercury vacuum, 200 pounds or more to 10 inches (EPA Service Practice Requirements).
  • System-dependent recovery equipment can’t be used on systems with more than 15 pounds of refrigerant, unless it’s a permanently attached pump-out unit (40 CFR 82.156).
  • Nitrogen alone is the preferred leak test gas; nitrogen with a trace of R-22 is better than pure refrigerant (EPA Section 608 Test Topics, Type 2).
06

Type III: low-pressure appliances

Chillers and other systems that run below atmospheric pressure: leak testing, purge units, recovery and recharging.

Key points (4)
  • A low-pressure appliance uses a refrigerant with a saturation pressure below 45 pounds per square inch absolute (psia) at 104°F, such as R-11, R-123 or R-245fa (40 CFR 82.152).
  • Low-pressure appliances must be evacuated to 25 millimeters of mercury absolute before opening, whatever the recovery equipment’s age (EPA Service Practice Requirements).
  • Heat the oil to 130°F before removing it, and circulate or drain the water during evacuation so the tubes don’t freeze (EPA Section 608 Test Topics, Type 3).
  • When recharging, introduce vapor before liquid, through the evaporator charging valve on centrifugals (EPA Section 608 Test Topics, Type 3).

Test day

What to bring to your EPA 608 test

  • Photo identification, such as a driver’s license, government ID card, passport or military ID
  • Your test confirmation or code from the program you booked with
  • Nothing else for the desk: notes and training materials aren’t allowed in a closed-book test, and Mainstream Engineering doesn’t allow a calculator on its online test

Before you go

  1. Work out which equipment you’ll service, then pick Type I, II, III or Universal to match.
  2. Choose a program from EPA’s approved list and check how it tests: in person, remote or mail-in.
  3. Study EPA’s test topics for Core and each type you’re taking. Training classes are voluntary; only the test is required.
  4. If you need the test read aloud, send the program a written request at least 30 days ahead.
  5. Keep your receipt and confirmation until your card arrives.
EPA: Certification Programs for Section 608 TechniciansEvery approved program is on this list, with notes on remote testing, Spanish tests and nationwide locations. You book and pay with the program, not with EPA.

Study options

Where to study

EPA doesn’t publish a study guide or a practice test of its own. It posts the topics each section covers, and it says some websites have free practice questions. Mainstream Engineering, one of the approved programs, gives away Type I training software with practice exams. Courses and apps for the other types are paid: in October 2026 SkillCat charged $10 a month and Faraday $199 for its course.

OptionPriceFree to useLinks
From EPA
EPA Section 608 Test TopicsOfficial topic listWhat each section of the test covers, from environmental impacts and the venting ban to recovery levels and chiller recharging. EPA doesn’t publish a study guide or practice test; this is its outline.
No charge; it’s a public EPA web pageThe whole list for Core, Type I, Type II and Type III
Approved programs
Mainstream Engineering (EPATest.com)Approved certifying organization: software, manuals, online and in-person testsApproved by EPA since January 26, 1994. Universal is offered online through ProctorU or in person with a proctor found through its testing locator. The course for the other types needs a purchased download code, and open-book exams are now bought and taken through an account on its site.
Type I open-book test $26.95 for the first attempt, $7.95 for each extra attempt, card includedType I training software for Windows with electronic manuals, interactive tools and unlimited practice exams, now with Spanish
SkillCatApp with training, practice tests and a proctored online examApproved by EPA since November 18, 2020, for online testing only, with Spanish. The exam runs in the app on a phone, computer or iPad with a virtual proctor, and SkillCat says the membership includes four attempts.
$10 a month after a 3-day free trialThe 3-day trial
FaradayOnline course with a proctored online examOn-demand videos, a study guide, unlimited practice exams and hundreds of practice questions, with lifetime access. Exams are proctored online on Tuesdays and Thursdays at 8 p.m. Eastern Time, on a computer only.
$199 for the course, the online exam and a physical cardNot listed
Air Conditioning Contractors of America (ACCA)Paper test through registered proctors, plus a guide and an online prep courseClosed-book paper tests in English, given by vocational schools, manufacturers, utilities and contractors acting as ACCA proctors. No online test yet. ACCA also sells a Technicians Guide and Workbook and a self-paced online prep course.
$32.95 a test when your proctor orders it, plus shippingNot listed
Interplay LearningVideo courses and practice tests for teamsCourses for Core, Type I, Type II and Type III on desktop, laptop, mobile or VR, with live online proctoring for the Universal exam. Built for employers, with an admin dashboard to assign courses and track results.
Not on its EPA 608 pageNot listed
ESCO InstituteApproved certifying organizationApproved by EPA since December 28, 1993. EPA’s list notes remote testing, a training manual and locations nationwide, and EPA names ESCO as a program that replaces lost cards.
Set by ESCO on its own siteNot listed

Prices and ratings checked October 2026.

FAQ

Common questions

What is EPA 608 certification?

It’s proof that you passed an EPA-approved test on handling refrigerants safely. EPA’s rules call you a technician if your work could release refrigerant: attaching or removing hoses and gauges, adding or removing refrigerant, adding or removing components, or cutting a refrigerant line. Painting a unit, rewiring an outside electrical circuit or tightening nuts and bolts doesn’t count. Installers, contractor employees, in-house maintenance staff and equipment owners can all be technicians. Servicing car air conditioners for pay needs Section 609 certification instead.

Which EPA 608 type do I need?

It depends on the equipment. Type I covers factory-sealed small appliances with 5 pounds of refrigerant or less, like window units and household refrigerators. Type II covers medium-, high- and very high-pressure equipment such as split systems, heat pumps and supermarket refrigeration. Type III covers low-pressure equipment, mainly chillers. Universal covers all three. You can only buy refrigerant for the appliances your certification covers.

Does EPA 608 certification expire?

No. EPA says Section 608 credentials don’t expire, and there’s no renewal. EPA can suspend or revoke a certificate if you break the rules or can’t show it the right recovery procedures, and it has kept the right to bring in recertification later through a notice in the Federal Register. It hasn’t done that.

What score do you need to pass the EPA 608 test?

EPA’s rules set the passing score at 70 percent for the closed-book Type I, Type II, Type III and Universal tests, and 84 percent for a Type I test in the mail-in format. The Air Conditioning Contractors of America (ACCA) and Mainstream Engineering grade Core and each type as separate 25-question sections. ACCA asks for 18 to 25 right on each section, and Mainstream gives its pass mark as 72 percent, or 18 of 25: 17 right would be 68 percent, just under EPA’s 70. At ACCA, a type section counts only once you’ve passed Core.

Do you need EPA 608 certification to buy refrigerant?

Yes, with a few exceptions. Since January 1, 2018 the sales restriction covers hydrofluorocarbons (HFCs) such as R-410A as well as ozone-depleting refrigerants like R-22. A seller may sell to you if you’re certified or if your employer shows written proof that it employs at least one certified technician. Section 609 technicians can buy motor vehicle refrigerant but not refrigerant for stationary equipment. Small cans of 2 pounds or less of car air-conditioning refrigerant with a self-sealing valve can still be sold to anyone.

Is there a separate R-410A certification?

Not from EPA. EPA requires Section 608 certification for the type of appliance, whatever refrigerant it uses, and has no certification just for R-410A. Some trade schools offer R-410A classes and certificates, but EPA says they aren’t equivalent to Section 608. Installing an R-410A mini-split still needs Section 608 certification if you add or remove refrigerant or connect pre-charged lines.

Can I work on equipment before I’m certified?

Only as a registered apprentice or a student. An apprentice registered with the US Department of Labor’s Office of Apprenticeship, or a state council it recognizes, can work under the close and continual supervision of a technician certified for that equipment, for up to two years from registering. Students may work on equipment in classroom or lab coursework. Other on-the-job training counts as service work and needs certification.

What changes for refrigerant technicians in 2027 and later?

The certification rules stay the same; the new dates come from EPA’s American Innovation and Manufacturing (AIM) Act rules in 40 CFR Part 84. By January 1, 2027, owners of commercial or industrial process refrigeration systems installed from 2017 through 2025 that hold 1,500 pounds or more of an HFC refrigerant must have automatic leak detection. From January 1, 2028, a used disposable cylinder you won’t use again goes to a reclaimer, a refrigerant supplier or a final processor that can remove the leftover refrigerant, unless a certified technician pulls it to 15 inches of mercury vacuum and signs a statement for the scrap yard or landfill. From January 1, 2029, supermarket systems, refrigerated transport and automatic commercial ice makers must be serviced with reclaimed refrigerant. The HFC leak repair rules in force since January 1, 2026, and EPA’s May 2026 proposal to change them, are on the Type II page.

What does EPA’s 2026 Technology Transitions rule change?

It covers new equipment, not your certification. EPA’s final rule of May 2026 sets a global warming potential (GWP) limit of 1,400 for new supermarket systems from January 1, 2027 until January 1, 2032. It also lets residential and light commercial air conditioners and heat pumps made in or imported into the US before January 1, 2025 still be installed.

Is EPA 608 certification the same as Section 609?

No. Section 609 is a separate program for motor vehicle air conditioning, with its own approved programs and its own test, and a 609 card doesn’t let you buy refrigerant for stationary equipment. Off-road vehicles with motor vehicle air conditioner (MVAC)-like systems, such as farm and construction equipment, are the overlap: you can use either Section 609 or Type II.

Sources: EPA · eCFR and 10 more. Checked October 2026.