Which special locations does BS7671 Part 7 cover?
| Section | Installation or location |
|---|---|
| 700 | General |
| 701 | Locations containing a bath or shower |
| 702 | Swimming pools and other basins |
| 703 | Rooms and cabins containing sauna heaters |
| 704 | Construction and demolition site installations |
| 705 | Agricultural and horticultural premises |
| 706 | Conducting locations with restricted movement |
| 708 | Caravan and camping parks and similar locations |
| 709 | Marinas and similar locations |
| 710 | Medical locations |
| 711 | Exhibitions, shows and stands |
| 712 | Solar photovoltaic (PV) power supply systems |
| 714 | Outdoor lighting installations |
| 715 | Extra-low voltage lighting installations |
| 716 | Power over Ethernet (PoE), new in Amendment 4 |
| 717 | Mobile or transportable units |
| 721 | Caravans and motor caravans |
| 722 | Electric vehicle charging installations |
| 729 | Operating and maintenance gangways |
| 730 | Onshore units of electrical connections for inland navigation vessels |
| 740 | Temporary installations at fairgrounds, amusement parks and circuses |
| 753 | Heating cables and embedded heating systems |
This list is the one in City & Guilds' 2382‑22 handbook, with Section 716 added. Amendment 4 introduced Section 716 on Power over Ethernet and made a major revision of Section 710, Medical locations.
How Part 7 works
Section 700 explains why Part 7 exists and how its numbering works. Each section's regulations modify or add to the general ones: Section 722, for example, changes the general requirements for protection against electric shock and adds rules on PME supplies, socket-outlets, external influences, isolation and RCD protection for EV chargers.
So for a job in a special location, read the general rules and the Part 7 section together. City & Guilds' learning outcome asks you to interpret how these sections affect the general requirements.
Recent changes to special locations
Amendment 1:2020 rewrote Section 722 on EV charging. Amendment 4:2026 added Section 716 on Power over Ethernet, made a major revision of Section 710, Medical locations, and added a schedule for recording supplementary bonding test results.
Bathrooms: Section 701
Section 701 has its own zones, IP ratings and RCD rules, and the IET's technical helpline says it often gets questions about it.
Sources: City & Guilds · IET and BSI · IET and 2 more. Checked October 2026.
- City & Guilds: 2382-22 qualification handbook (January 2025, v1.2) ↗
- IET and BSI: BS 7671:2018 Amendment 1:2020, read-only copy (February 2020) ↗
- IET: Ensure you are up to date with BS 7671 ↗
- IET: Section 701, Locations containing a bath or shower (Geoff Cronshaw, written for BS 7671:2008, undated) ↗
- IET: IET & BSI officially publish Amendment 4 (2026) to BS 7671:2018 (15 April 2026) ↗
Rules and fees can change, so check the official site before your test.